Thermal insulation for housing and small buildings
Thermal insulation for housing and small buildings – revised Standard published
Standards New Zealand has published a revised Standard specifying Thermal insulation – Housing and small buildings, NZS 4218:2009, which supersedes NZS 4218:2004.
NZS 4218 specifies thermal insulation requirements for housing and small buildings for users of the Standard – architects, designers, building consent authorities, and window and glass companies.
‘The Standard is also useful for the building industry including window and glass manufacturers, insulation manufacturers, and manufacturers and suppliers of building products so that they can provide advice and stock appropriate products,’ says Michael Camilleri, committee Chair, from BRANZ. ‘Ambiguities in the previous version of NZS 4218 have been resolved, and there is additional guidance with more worked examples.’
The revised version of NZS 4218:
• includes modified R-value tables and
brings the Standard into line with these increased
performance requirements. The construction R-values in this
Standard result in a low life cycle cost, based on current
knowledge of insulation costs, energy costs, and heating
behaviour
• clarifies the three different ways of
working out R-values (Schedule method, Calculation method,
and Modelling method) and ensures consistency between the
different methods
• includes clearer
definitions.
Some of the most significant changes are:
• adjusted R-values to reflect improved energy
efficiency
• changes to the calculation method to
ensure adequate thermal performance is not compromised by
large glazing areas
• a revised modelling method to
take account of recent research, and to make it easier to
use with recent computer modelling packages
• new
requirements for high thermal mass construction to ensure
that the thermal mass is adequate and effective
• a
revised appendix (now Appendix C) on windows and
glazing
• a new informative Appendix D provides
guidance on alterations and how they can achieve higher
thermal resistance
• more worked examples in
informative Appendix F
• the new term construction
R-values has been introduced to distinguish the performance
values in this Standard from insulation material
R-values.
‘There is more clarity on the use of doors, skylights, decorative glazing, and louvres,’ says Allan Sage, committee member and Glass Association of New Zealand Technical Advisor. ‘Appendix D – Windows and Glazing has been revised, offering more glazing options and guidance for users wanting to calculate other glass and frame combinations. A new term (RWindow) has been introduced to overcome confusion over the R-value for glass only (RCOG) and the total window R-values (RWindow).’
‘The major change for the window industry is the reduction of the limit on glazing area from 50% to 40% for the Calculation method. The Modelling method must be used for a glazing area over 40% of the total wall area. This will see more modelling of complex houses in the future, which GANZ believes is a positive move to stop over-heating and under-heating issues with modern house design.’
To order or download NZS 4218:2009, visit www.standards.co.nz and enter keyword 4218 in the search area, email enquiries@standards.co.nz, or call customer services on 0800 782 632.
Get the latest Standards news at www.standards.co.nz/touchstone
ENDS